Saratov JOURNAL of Medical and Scientific Research

CROHN’S DISEASE DIAGNOSTICS IN ACUTE STAGE WITH THE USE OF HIGHLY EFFECTIVE LIQUID CHROMATOGRAPHY BLOOD SERUM

Summary:

15 patients with the endoscopically and morphologically verified diagnosis of the Crohn’s disease and 14 healthy humans at the age of 23- 24 years have been examined. The Crohn’s disease index activity was 235 - 310 units. The possibility highly effective liquid chromatography blood serum use for diagnosis of the disease has been studied. A blood serum dried extract has been investigated on the "Milichrome A 02" chromatograph (Novosibirsk, "Econova "joint-stock company). The chromatograms have been treated with the use of a multilevel cluster analysis with a pathologic three-measured state form, differing from a healthy human. A diagnostic sensitivity and accuracy of the method has achieved 100%.

AttachmentSize
2008_02_082_085.pdf294.91 KB

No votes yet