Saratov JOURNAL of Medical and Scientific Research

Микроинвазивная хромовитрэктомия 25+ Gauge в лечении пациентов с идиопатиче-скими макулярными отверстиями

Year: 2013, volume 9 Issue: №1 Pages: 98-100
Heading: Ophtalmology Article type: Original article
Authors: Стебнев B.C., Малое В.М.
Organization: Samara State Medical University
Summary:

Purpose: The features and results of the surgical treatment of idiopathic macular holes with application of modern microinvasive 25+ Gauge chromovitrectomy and endovitriol dye BrilliantBlue G have been studied in the article. Materials and methods: The surgical treatment of 45 patients with macular holes aged 58,4 +/-10,3 years has been performed. Results: Microinvasive 25+Gauge chromovitrectomy with application of endovitriol dye BrilliantBlueG allows to achieve high anatomic and functional results in treatment of idiopathic macular holes in the early and remote periods of supervision. Intraoperative and postoperative complications have been analyzed with anatomic and functional results. Conclusion: It has been revealed that modern microinvasive 25+ Gauge chromovitrectomy with application of endovitriol dye BrilliantBlueG makes the surgery easier and more effective.

AttachmentSize
2013-01_098-100.pdf268.06 KB

No votes yet